1334A

Fieldbus, 1 Pr #18 Str TC, PO Ins, OS+TC Brd, PVC Jkt, CMG

...
Fieldbus, 1 Pair 18AWG (7x26) Tinned Copper, PO Insulation, Overall Beldfoil®+Tinned Copper Braid(65%) Shield, Orange PVC Outer Jacket, CMG
Request Sample Get Product Alerts
Specifications
Product Overview

Suitable Applications

harsh environment digital and serial two-way communication, oil and gas extraction and refining sites, petrochemical, Profibus process automation or Foundation FieldBus process automation, extreme temperature environments, exposure to humidity/moisture, dust, and oil, remote locations long distance applications, etc.

Construction Details
Conductor
Element Number of Element Size Stranding Material
Pair(s) 1 18 7x26 TC - Tinned Copper
Insulation
Material Color Code
PP - Polypropylene Blue & Orange
Outer Shield
Shield Type Material Coverage
Tape Bi-Laminate (Alum+Poly) 100%
Braid Tinned Copper (TC) 65%
Outer Jacket
Material Nom. Diameter Ripcord
PVC - Polyvinyl Chloride 0.287 in Yes
Electrical Characteristics
Electricals
Nom. Conductor DCR Max. Capacitance Unbalance Nom. Capacitance Cond-to-Shield Nom. Characteristic Impedence Nom. Velocity of Prop. Max. Current
5.86 Ohm/1000ft (19.2 Ohm/km) 1.2 pF/ft (3.9 pF/m) 45 pF/ft 100 Ohm 66% 5.2 Amps per Conductor
High Frequency (Nominal/Typical)
Nom. Insertion Loss (Attenuation)
0.069 dB/100ft
High Frequency
Max. Insertion Loss (Attenuation) Max./Min. Input Impedance (unFitted)
0.091 dB/100ft 100 Ohm
Voltage
UL Voltage Rating
300 V RMS
Mechanical Characteristics
Temperature
UL Temperature Operating
90°C -40°C to +105°C

Max. Pull Tension

59 lbs (27 kg)

Bulk Cable Weight

60 lbs/1000ft (89 kg/km)

Standards and Compliance

Environmental Suitability

Indoor, Outdoor, Sunlight Resistance, UV Resistance, Oil Resistance

Flammability / Reaction to Fire

UL1685 FT4 Loading, 1202, IEC 60332-3-24

CPR Compliance

CPR Euroclass: Eca

NEC / UL Compliance

Article 725, Article 727, Article 800

CEC / C(UL) Compliance

CMG

European Directive Compliance

EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)

UK Regulation Compliance

UKCA Mark

History

Update and Revision

Revision Number: 0.544 Revision Date: 05-25-2023

Part Numbers
Item # Color Putup Type Length UPC
1334A 0061000 Blue, Light Reel 1,000 ft 612825112143
1334A 0063280 Blue, Light Reel 3,280 ft 612825112150
1334A 0031000 Orange Reel 1,000 ft 612825112112
1334A 0033280 Orange Reel 3,280 ft 612825112136
Resources